Forensic hair analysis detected emerging cannabinoids in 23 of 100 samples

Paper title: Development and Validation of a UPLC-MS/MS Method for the Determination of Emerging Synthetic, Semi-Synthetic and Related Cannabinoids in Human Hair.

Molecules (Basel, Switzerland) 100 human hair samples from subjects who tested positive for Δ9-THC during forensic assessments following driving-license suspension

The short answer

A validated hair-testing method detected targeted cannabinoids in 23 of 100 samples and identified 14 different compounds. The samples came from people who tested positive for Δ9-THC during forensic assessments following driving-license suspension; this selected sample cannot show how common these compounds are more broadly or establish when or how they were used.

Design
Lab analysis (chemistry)
People
n = 100
100 human hair samples from subjects who tested positive for Δ9-THC during forensic assessments following driving-license suspension
Evidence
Lab and cells
Cells or chemistry, not people
Source
Peer reviewed
Molecules (Basel, Switzerland)

What it can't tell you

The tested samples were from a selected forensic group who had tested positive for Δ9-THC. The abstract notes wider level-specific variability in method performance for selected analytes.

What the study found

  1. The validated method measured 26 targeted cannabinoids in human hair, with accuracy and precision meeting the study’s predefined criteria.
  2. Target cannabinoids were detected in 23 of 100 forensic hair samples, and 14 different compounds were identified.
  3. MDMB-4en-PINACA, 9R-HHC-O, and ADB-BUTINACA were the most frequently detected compounds in the tested samples.

Each finding is supported by the abstract.

The full summary

This study developed and validated a UPLC-MS/MS method to identify and measure 26 synthetic, semi-synthetic, and related cannabinoids in human hair. The method showed sensitive detection and met the stated accuracy and precision criteria, with some variability in performance for selected compounds.

The researchers then applied it to 100 hair samples from people who had tested positive for Δ9-THC during forensic assessments after driving-license suspension. Cannabinoids targeted by the method were found in 23 samples, representing 14 different compounds. These results show the method can detect multiple emerging cannabinoid types in hair; they do not establish when or how the compounds were used, or how common their use is beyond this selected forensic sample.

Original abstract

Synthetic cannabinoids (SCs) are an evolving group of new psychoactive substances (NPSs), characterized by structural diversity and continuously emerging analogues. Their detection in biological matrices is challenging because of low concentrations, rapid metabolism, and incomplete coverage by routine methods. Hair analysis offers a detection window for retrospective exposure assessment. This study aimed to develop and validate an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous identification and quantification of 26 synthetic, semi-synthetic, and related cannabinoids in human hair and to assess its applicability to authentic forensic samples. The method was validated for linearity, limits of detection (LOD) and quantification (LLOQ), accuracy, precision, matrix effect, recovery and process efficiency, with additional robustness assessments under freeze-thaw and processed-extract conditions, and was then applied to n = 100 hair samples collected from subjects tested positive for Δ9-tetrahydrocannabinol (Δ9-THC) during forensic assessments following driving license suspension. LODs were 1.56-3.13 pg/mg, LLOQs 6.25-12.5 pg/mg, and R2 ≥ 0.992; accuracy and precision met the predefined acceptance criteria, while ME, RE, and PE showed generally consistent mean performance with wider level-specific variability for selected analytes. Target cannabinoids were detected in 23/100 samples, with 14 different compounds identified. MDMB-4en-PINACA, 9R-HHC-O, and ADB-BUTINACA were the most frequently detected compounds. The method enabled sensitive and reliable detection of multiple emerging cannabinoid classes in hair, supporting the continuous updating of targeted analytical panels in response to the evolving NPS landscape.

Paper details 5 authors, keywords and identifiers

Authors

  • Leonardo Romani Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier, 1, 00133 Rome, Italy.
  • Giulio Mannocchi Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier, 1, 00133 Rome, Italy.
  • Lucrezia Stefani Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier, 1, 00133 Rome, Italy.
  • Luigi Tonino Marsella Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier, 1, 00133 Rome, Italy.
  • Roberta Tittarelli Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier, 1, 00133 Rome, Italy.

Subjects

Keywords (MeSH)

Humans · Hair · Cannabinoids · Tandem Mass Spectrometry · Liquid Chromatography-Mass Spectrometry · Chromatography, High Pressure Liquid · Limit of Detection · Reproducibility of Results

Identifiers

PMID
43029134
DOI
10.3390/molecules31213816
PMC
PMC13764793

Your stash, decoded.