Human laboratory pilot found needle-free sampling feasible in inhaled THC study

Paper title: Maintaining IV Patency Throughout Pharmacokinetic Studies Through a Needle-Free Blood Draw Device.

Pharmacology research & perspectives Participants in a human laboratory study of inhaled Δ8-THC, Δ9-THC, and placebo; number and location not stated

The short answer

A pilot human laboratory study found that needle-free blood collection was generally sufficient to keep the planned schedule during sessions involving inhaled Δ8-THC, Δ9-THC, and placebo, though about 40% of access sites needed replacement. The abstract does not give the participant count and says further studies are needed to compare analytical performance and access durability with conventional sampling.

Design
Human lab study
People
Participants in a human laboratory study of inhaled Δ8-THC, Δ9-THC, and placebo; number and location not stated
Evidence
Human lab
People in a controlled lab test
Source
Peer reviewed
Pharmacology research & perspectives

What it can't tell you

The abstract describes a pilot and says further studies are warranted to compare analytical performance and access durability with conventional venous sampling approaches.

What the study found

  1. In a pilot human laboratory study of inhaled Δ8-THC, Δ9-THC, and placebo, needle-free sampling was generally sufficient to maintain the planned sampling schedule.
  2. About 40% of vascular access sites required replacement, most commonly within the first hour and typically after poor initial blood return.
  3. Participants reported that the procedures were acceptable; the abstract reports one mild access-related adverse event, localized bruising.

Each finding is supported by the abstract.

The full summary

This pilot study tested whether a needle-free device could collect repeated blood samples through an existing IV catheter during a pharmacokinetic study of inhaled Δ8-THC, Δ9-THC, and placebo. Participants completed three dosing visits, with blood collection scheduled at nine time points over about eight hours. The abstract does not report the number of participants.

Participants found the procedures acceptable, and sampling was generally sufficient to keep the planned schedule despite slower blood flow than with standard venipuncture. About 40% of vascular access sites needed replacement, often early in a visit; one mild access-related bruise was reported. This pilot supports operational feasibility, but it does not establish how the device compares with conventional sampling in analytical performance or access durability.

Original abstract

Pharmacokinetic (PK) studies require temporally precise measurements of drug concentrations in biological matrices, most commonly whole blood or plasma. However, repeated venous sampling may increase participant burden and complicate PK-intensive study designs. Needle-free blood collection devices that access peripheral intravenous (IV) catheters may provide an alternative approach to repeated venipuncture while maintaining sampling schedules and specimen quality. This pilot study evaluated the feasibility of integrating the PIVO Pro needle-free blood collection device into a PK-intensive human laboratory study of inhaled Δ8-tetrahydrocannabinol (Δ8-THC), Δ9-THC, and placebo. Participants completed a screening visit and three dosing visits conducted in a university research facility equipped with a full-scale driving simulator. During each dosing visit, venous blood samples were collected at nine time points over approximately 8 h through an indwelling peripheral IV catheter using the PIVO device. All participants reported that study procedures, including blood collection, were acceptable. Approximately 40% of vascular access sites required replacement, most commonly within the first hour and typically associated with poor initial blood return. Despite slower flow compared with standard venipuncture, sampling was generally sufficient to maintain the PK sampling schedule. One mild adverse event related to vascular access (localized bruising) was observed. These findings demonstrate the operational feasibility of needle-free blood collection through indwelling IV catheters in a PK-intensive research protocol conducted outside a traditional clinical research unit. Further studies are warranted to compare analytical performance and access durability relative to conventional venous sampling approaches.

Paper details 3 authors, keywords and identifiers

Authors

  • William Naviaux Pharmaceutical Sciences, School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • David Leinweber Department of Family Medicine and Community Health, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Heather Barkholtz Pharmaceutical Sciences, School of Pharmacy, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Subjects

Keywords (MeSH)

Adult · Female · Humans · Male · Middle Aged · Young Adult · Blood Specimen Collection · Catheterization, Peripheral · Catheters, Indwelling · Dronabinol · Feasibility Studies · Phlebotomy · Pilot Projects

Identifiers

PMID
42885759
DOI
10.1002/prp2.70333
PMC
PMC13673574